HC 15-95
Condensing Boiler
Excellent value for money, the HC series offers an economical solution to all your home heating needs without sacfificing reliabilty. DHW demand priority standard on all HC models. Pair wih our IBC indirect tanks for a complete system.

Features
Technical Data
Connections
Touch Panel
Documentation
Features
· Unique and innovative single pass copper / aluminum heat exchanger, ensuring greater efficiency and eliminating water side corrosion. |
· Up to 96% AFUE, with full ASME-rated vessel. |
· Built-in boiler pump. |
· PVC/CPVC/PPs approved. |
· 2” & 3” venting options available. |
· Contractor friendly, easy to install, maintain and service. |
· Up to 6.25:1 turndown ratio of better load matching. |
· Fewer parts ensuring greater reliability. |
· Outdoor reset technology increases efficiency by lowering the water temp automatically. |
· Reset heating – Set point – DHW. |
· Includes air vent, outdoor sensor & relief valve. |
· Exceptional value and longevity. Over 1.5 million installed. |
· Better reliability and durability. |
· 5 Year manufacturer’s parts warranty. |
· 10 year limited heat exchanger warranty. |
Technical Data
SPECIFICATIONS | HC 13-50 | HC 15-95 | HC 20-125 | HC 33-160 |
CSA Input (Natural Gas or Propane *) – MBH | 13.5 – 51 | 15 – 95 | 20 – 125 | 33 – 160 |
CSA Input (Natural Gas or Propane *) – KW | 3.95 – 14.94 | 4.4 – 27.8 | 5.6 – 36.6 | 9.7 – 46.9 |
CSA Output – MBH | 12.4 – 45.4 | 14.5 – 85.9 | 18.6 – 110.8 | 30.4 – 140.0 |
CSA Output – KW | 3.64 – 13.3 | 4.3 – 25.0 | 5.4 – 32.5 | 8.9 – 41.0 |
A.F.U.E | 95% | 95% | 95% | 94% |
Min gas pressure (Nat. Gas or Propane) – inch w.c. | 5 | 5 | 5 | 5 |
Max gas pressure (Nat. Gas or Propane) – inch w.c. | 14 | 14 | 14 | 14 |
Power (120Vac/60Hz) – Watts @ full fire with internal pump | 126 | 128 | 130 | 164 |
Weight (empty) – lbs/Kg | 84 / 38 | 96 / 44 | 96 / 44 | 96 / 44 |
Pressure vessel water content – USG/Liters | 0.37/1.4 | 0.37/1.4 | 0.5/1.9 | 0.5/1.9 |
Max boiler flow rate – USgpm | 9 | 10 | 11 | 11 |
Min boiler flow rate – USgpm | 2 | 2 | 3 | 3 |
Max operating pressure – Space Heating Coil – psig | 43.5 | 43.5 | 43.5 | 43.5 |
Approved installation altitude – ASL | 10,000 ft | 10,000 ft | 10,000 ft | 10,000 ft |
Ambient temperature – Low (°F/°C) | 32/0 | 32/0 | 32/0 | 32/0 |
Ambient temperature – High (°F/°C) | 122/50 | 122/50 | 122/50 | 122/50 |
Max relative humidity (non-condensing) | 90% | 90% | 90% | 90% |
Min water temperature – Space Heating (°F/°C) | 50/10 | 50/10 | 50/10 | 50/10 |
Max water temperature – Space Heating (°F/°C) | 194/90 | 194/90 | 194/90 | 194/90 |
Max equivalent vent length 2″ (each side) | 35′ | 35’ | 35′ | 35′ |
Max equivalent vent length 3″ (each side) | 120′ | 120′ | 120′ | 120′ |
Connections
PIPING CONNECTIONS / MEASUREMENTS | ||
DESCRIPTION DC SERIES BOILERS / WATER HEATERS | ||
A | Exhaust Outlet | 3″ Schedule 40 |
B | Combustion Air | 3″ Schedule 40 |
E | Heating Water Inlet (Return) | 1″ Male NPT |
F | Heating Water Outlet (Supply) | 1″ Male NPT |
G | Gas Inlet | 1/2″ Male NPT |
H | Condensate Outlet | 3/4″ Hose |
I | Knock-out (3) | 1/2″ |
MODEL | HEIGHT |
HC 13-50 | 26.6″ [676mm] |
HC 15-95 | 29.0″ [736mm] |
HC 20-125 | 31.3″ [796mm] |
HC 33-160 | 31.3″ [796mm] |
Touch Panel
TOUCH PANEL CONTROL | |||
The HC controller functions as an interactive touch-sensitive panel with buttons that light up, showing indicators such as numbers, icons, or letters. Some of these lit indicators signify boiler operational status. Other indicators enable you to program the boiler. |
Documentation
Download List of Manuals
↓ HC Series Installation & Operating Instruction Manual |
↓ HC Series User Manual |
↓ HC Series Controller Manual |
Download List of Literature
↓ HC Series Sales Brochure |
↓ HC Series Submittal |